Premrique — Sapphire Serpent logoPremrique

SCADA Defense · IEC 62443 · Barcelona

Engineering Resilience.
Protecting Clean Energy.

I'm a Senior Cybersecurity & OT Network Architect at DNV GreenPowerMonitor. I design fault-tolerant industrial networks, deploy zero-trust architectures, and safeguard utility-scale solar and wind across the European grid.

5+ GW
Renewables monitored
150+
Substations hardened
<20ms
Moxa ring failover
0
Critical OT breaches
Premkumara Viswanathan

Premkumara Viswanathan

Senior Cyber & OT Architect · DNV

● ACTIVE
linkedin.com/in/premku

01 · The Expat Narrative

Bridging continents & disciplines.

Prem at Nyhavn harbour, Copenhagen

Adaptability & global vision — UPC BarcelonaTech alumnus.

  1. Phase 01 · Chennai, India

    2012 – 2016

    Mechanical Precision & Product Design

    Began as a product design engineer solving mechanical tolerances and system constraints — building a tactile intuition for how physical equipment and actuators behave in the real world.

  2. Phase 02 · Barcelona, Spain

    2016 – 2018

    Master's in Aerospace Science & Technology

    Relocated to Catalonia for UPC BarcelonaTech. Mastered mission-critical systems, telemetry links, orbital mechanics, and multinational collaboration.

  3. Phase 03 · Deep-Dive Mastery

    Self-taught

    Enterprise Networking Pivot

    Built an extensive home lab mastering routing, switching, and IPsec crypto fabrics, dissecting every protocol layer through the Cisco CCNA curriculum.

  4. Phase 04 · DNV GreenPowerMonitor

    Current

    Senior Lead, European SCADA & OT Defense

    Bridging PLCs, inverters, and substation RTUs with enterprise cybersecurity — protecting multi-gigawatt renewable assets feeding the clean energy transition.

02 · Technical Arsenal

OT architecture & defense grid.

Hardened Network Fabrics

  • ◆Fortinet FortiGate active-passive clusters
  • ◆Cisco Catalyst, ASA, OSPF/BGP
  • ◆Moxa Turbo Ring & Turbo Chain
  • ◆Site-to-site IPsec & ZTNA

Systems & Hypervisors

  • ◆VMware ESXi & vCenter hardening
  • ◆Hyper-V failover clustering
  • ◆Windows Server, AD, offline WSUS
  • ◆Redundant iSCSI SAN & Synology NAS

OT Protocols

  • ◆Modbus TCP/RTU
  • ◆DNP3 / Secure
  • ◆IEC 60870-5-104
  • ◆OPC UA / DA
  • ◆Suricata IDS rules

Compliance

  • ◆IEC 62443 — SL-3 ready
  • ◆NIST SP 800-82
  • ◆ISO/IEC 27001
  • ◆EU NIS2 Directive

03 · Production Impact

Impact at scale.

April 2026 – Present · Barcelona, Spain

Senior Cybersecurity Engineer · DNV GreenPowerMonitor

Senior technical authority and highest escalation point for critical IT/OT infrastructure. Architecting zero-trust perimeters across multi-gigawatt plant fleets, driving IDS/IPS rollout, and hardening zones to IEC 62443.

April 2024 – April 2026 · Barcelona, Spain

IT Systems Engineer · DNV GreenPowerMonitor

Deployed bare-metal hypervisors running SCADA for utility-scale solar and wind. Engineered Moxa redundancy rings, FortiGate policies, NAT traversal, and site-to-site IPsec meshes.

Featured case study · Published on LinkedIn

Breakdown of Key IT/OT Cybersecurity Trends in Renewable Energy

Why IT/OT cybersecurity is now a customer issue, a business issue and, increasingly, a regulatory one for critical infrastructure operators — from the gap between compliance and true resilience to visibility, patching lifecycles, and driving SecOps from detection to response.

◆ Compliance ≠ resilience◆ Patching lifecycle◆ Detection → response◆ Regulatory pressure (NIS2)

Read the full article on LinkedIn →

Featured case study

150 MW Solar PV — zero-trust segmentation

Replaced unmanaged switches with a dual Moxa Turbo Chain, isolated Modbus into dedicated VLANs, and deployed FortiGate inspection at the substation demarcation.

Failover: 45 s → <18 ms · zero lost telemetry records